Fire Sense 55006 Instruction Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
Gas valve may be OFF Turn the gas valve ON
Fuel tank empty Refill LP gas tank
Orifice blocked Clean or replace orifice
Air in supply system Purge air from lines
Pilot will not light
Loose connection Check all fittings
Debris around pilot Clean dirty area
Loose connection Tighten connection
Thermocouple bad Replace thermocouple
Gas leak in line Check connection
Pilot will not stay on
Lack of fuel pressure Fuel tank is near empty
Pressure is low Fuel tank is near empty
Orifice blocked Remove, clean and replace
Control valve not ON Turn valve to ON
Thermocouple bad Replace thermocouple
Burner will not light
Pilot light assembly bent or not in
correct location
Place pilot in proper position and
retry